What is HOMER Pro?
HOMER (Hybrid Optimization Model for Multiple Energy Resources) began at the US National Renewable Energy Laboratory (NREL) in the early 1990s and is now developed and distributed by UL Solutions. HOMER Pro is a Windows-only desktop program; on a Mac it needs a Windows emulator such as Parallels, which UL does not support. For behind-the-meter C&I bill savings UL sells HOMER Grid, and for utility-scale storage revenue, HOMER Front.
Once a project mixes PV, wind, batteries, a generator and perhaps a grid connection, spreadsheet sizing stops giving reliable answers. HOMER Pro simulates each candidate combination over a full year and ranks the workable ones by lifetime cost, for systems from village power and island utilities to grid-connected campuses and military bases. It suits microgrid developers, off-grid planners, feasibility consultants and researchers, not installers who need roof layouts or sales proposals.
Pros and Cons
Pros
- Sizes PV, wind, storage and generators together, so trade-offs between them show up in the numbers
- A ranked list of feasible systems lets you show clients or funders the alternatives, not a single answer
- NPC, LCOE, IRR and emissions outputs drop straight into a feasibility study
- Handles off-grid and grid-connected systems, including outages and grid extension (Advanced Grid module)
- Widely used: UL reports more than 250,000 HOMER users in over 190 countries
Cons
- Steep learning curve: useful results need a grasp of dispatch, costs and constraints
- Dated interface, and Windows only: no web, mobile or native Mac version
- Results are only as good as your load data and cost inputs
- No PV layout, 3D shading or client-ready proposal visuals
- Base license ($187.50/month) has no add-on modules; grid tariffs, battery degradation or multi-year analysis cost extra
Features
1. System optimization
You give each component a few sizes, or let the HOMER Optimizer pick them, and HOMER simulates every combination over a year in time steps of one minute to one hour, often thousands of systems per run. Systems that break your constraints (capacity shortage, minimum renewable fraction, operating reserve) are dropped; the rest are ranked by net present cost or another metric you choose.
2. Detailed financial analysis
Each system gets a net present cost (NPC), levelized cost of energy (LCOE), operating cost, cash flow and emissions totals. Comparing it with a base case, such as an existing diesel plant, adds IRR and ROI.
3. Sensitivity analysis
Enter several values for an uncertain input, such as fuel price, load or wind speed, and HOMER reruns the optimization for each. The optimal system type plot shows where the best design changes, for example the diesel price at which PV and storage win.
4. Microgrid and off-grid modeling
The base license covers PV, wind, batteries, fuel generators and a simple grid connection, enough for a solar-diesel-battery mini-grid. Nine add-on modules extend it: Biomass, Hydro, Combined Heat and Power, Hydrogen, Advanced Load, Advanced Grid (tariffs, demand charges, outages, grid extension), Advanced Storage (battery degradation), Multi-Year and MATLAB Link.
5. Resource data integration
Solar, wind and temperature data can be downloaded inside the program or imported as time series. Without meter data, HOMER builds a synthetic year of load from typical daily profiles.
6. Component flexibility
Each component takes your own capital, replacement and O&M costs, lifetime and technical curves, and most of these can be set as sensitivity variables.
HOMER Pro Pricing
HOMER Pro is sold as a monthly or annual subscription. Standard single-user commercial licenses (Base, Professional and Expert) cost $187.50 – $568.50/month, or $1,575 – $4,650 when billed annually. Every tier includes the core simulation, optimization and sensitivity tools, software updates and basic support. Base includes no add-on modules but lets you buy them individually, Professional adds any 4 of the 9 modules plus 6 hours of instructor-led training, and Expert includes all modules and the training.
Academic licenses for faculty and staff (research and teaching only) are 50% off, from $93.75/month. Students pay $59.89 for four months or $108.89 for a year, all modules included. First-time users get a 14-day trial with all modules, though UL points anyone who needs to create reports to a paid license.
Integrations
HOMER Pro is a sizing and economics engine with few direct connections to other software.
- MATLAB Link module for your own dispatch algorithm; commercial controllers built with HOMER’s C++ SDK can also be modeled
- Works alongside tools like Aurora Solar for visual layouts
- Can complement platforms like HelioScope for detailed PV design
- Summary report, results tables and time series data export
How to Use HOMER Pro

Keep the first model small: one load, the components you are seriously considering and a few sizes for each. The built-in design wizard can set it up for you.
Define your load profile
A rough daily profile is enough for a first pass; replace it with measured data before you trust the sizing.
Add your energy sources
Download solar, wind and temperature data for the site and set fuel prices. Swap in measured site data later if you have it.
Choose system components
Add PV, batteries, generators and a converter with a few sizes each, or let the optimizer choose the sizes.
Enter costs and constraints
Capital, replacement and O&M costs, the discount rate, project lifetime and constraints decide which system ranks first. If a result looks odd, check these inputs first.
Run the simulation
Run time grows with the number of sizes and sensitivity values, so a coarse search followed by a finer one around the leaders is quicker than one huge run.
Analyze results
Read the optimization table of ranked systems, then open the leaders for cost breakdowns, component outputs and time series plots.
Adjust and repeat
Expect several passes: narrow the size ranges, refine the inputs that drive the result and rerun.
FAQ
Do I need to be an expert to use HOMER Pro?
No, but you need to understand your inputs (load data, costs, discount rate, dispatch), because HOMER optimizes whatever it is given. The online manual documents each one.
Is HOMER Pro only for large projects?
No. A single off-grid building with PV, a battery and a generator is a sensible model; the payoff grows with every extra component and uncertain input.
Can it replace solar design tools?
No. HOMER models PV output with a derating factor and has no site layout or 3D shading. Use a tool like HelioScope for that, and HOMER for sizing and economics.
How accurate are the results?
As accurate as your inputs. A guessed load profile or an outdated fuel price will skew the ranking, so run sensitivities on the inputs you trust least.
Can I use it without internet access?
Mostly. HOMER Pro is a Windows desktop application that runs simulations on your own computer, but you need an internet connection to download the license file and to pull solar, wind and temperature data from HOMER’s online resource service.
Is HOMER Pro worth investing time in?
Yes, if you size hybrid or off-grid systems regularly. For an occasional project, test a real case in the 14-day trial first; for a thesis, the student license is far cheaper.